Home /Guides /How to Choose a Pressure Transmitter for Water and Wastewater

How to Choose a Pressure Transmitter for Water and Wastewater

Define the pressure range first

Choose a range where normal operating pressure sits around the middle of the span. A transmitter that runs near the top of its range has less margin for pressure spikes; one that runs too low loses resolution.

For water and wastewater, common measurements include:

  • Pump discharge pressure
  • Filter differential pressure
  • Tank level (hydrostatic pressure)
  • Pipeline pressure
  • Blower and compressor pressure

Check the maximum pressure and surge conditions, not just the normal operating point. Overpressure and burst ratings matter on pump systems.

Gauge, absolute or differential?

  • Gauge: referenced to atmosphere; the usual choice for pump and pipe pressure.
  • Absolute: referenced to vacuum; used where barometric changes matter.
  • Differential: for filter and flow measurement; requires two ports.

Most water and wastewater pressure transmitters are gauge or differential.

Output signal

  • 4–20 mA: the standard for long cables and PLC/DCS inputs.
  • 0–10 V: common in compact OEM and HVAC panels.
  • RS485 Modbus: useful for digital networks and multi-drop installations.

Use our 4–20 mA calculator to check the current at a given pressure.

Wetted material and connection

316L stainless steel is the standard wetted material for water and wastewater. Confirm the process connection (G1/4, G1/2, 1/4 NPT, 1/2 NPT), the seal material and the cable entry. For dirty water or sludge, a flush diaphragm or a larger port may be easier to clean.

Environment and protection

  • IP rating: confirm the enclosure protection for washdown or outdoor installation.
  • Condensation: use a cable gland and installation that keeps water away from the electronics.
  • Surge: pump systems can generate voltage spikes; use surge protection where needed.
  • Temperature: check both the medium and ambient temperature.

Installation tips

  • Install downstream of the pump where flow is stable.
  • Use a isolation valve and a drain point for maintenance.
  • Avoid mounting at the bottom of a tank where sediment collects.
  • Keep the cable away from VFD output cables.

Ordering checklist

  • Pressure range and overpressure
  • Gauge, absolute or differential
  • Output: 4–20 mA, 0–10 V or RS485
  • Process connection and seal
  • Wetted material
  • IP rating and cable length
  • Calibration certificate required?

See our pressure transmitters for compact, sanitary, high-temperature and display versions, or contact us with the range and connection.